Joining Straight Lengths of Tubing
Both branch lines and the trunk lines may require lengths of
tubing longer than those 8´ sections supplied. Use stop
couplings to join two straight lengths of tubing. Insert one
end of the tubing into the stop coupling; join the
second length of tubing into the other end of the stop
coupling. Stop couplings are also used to join long
vertical branches which run from one level to another level
of a house.
Connecting a Branch Line
A branch line connects the inlet line to the trunk line. Follow
the methods previously described for aligning, marking and
cutting the inlet tubing. Attach a 90° elbow and run tubing from
the inlet line to the trunk line.
To align and measure the branch line, attach a 90° tee
fitting to the trunk line. Make sure the tee connects with the air
flow going toward the power unit. Align, measure, and mark
the branch line for inserting it into the tee fitting. Then, cut the
branch line to length and insert it into the tee. Check to make
sure the cut is straight and even. Connect the next section of
tubing to the out-take side of the tee fitting. Continue the trunk
line until you come to another branch line junction point.
27
Branch Line
Make sure
air flows
toward
Power Uni t
To Power Unit
AO0057A