NuTone VX550 Installation Guide Page 22

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 21
IN WALL INSTALLATIONS
Refer to Figure 47.
ORIGINAL VACPAN can be installed between wall studs
in side walls.
ORIGINAL VACPAN should be located tight to one side
in stud space.
Once the ORIGINAL VACPAN location is determined, cut
a 6¾” long x 1¾” high slot in the wall and baseboard to
accept the ORIGINAL VACPAN.
The 2 x 4 wall bottom plate between the 2 studs must be
removed. This can be achieved from below using a hole saw.
In new home construction, the bottom wall plate can be
removed directly. A 6¾” length of 2 x 4 can be used as a
temporary rough in block, that will force all trades to
finish around, leaving a slot for the ORIGINAL VACPAN.
Floor contractor must run flooring under block.
Run vacuum tube piping and low voltage wire from the
main line to ORIGINAL VACPAN location.
Access for final piping connections must be made.
Access from Below
If access is available from below, cut an access
hole through the subfloor underneath the wall between
the studs, positioned so that final piping connections can
be made by reaching through the access hole.
Access Through Wall
Access can be made through the finished wall.
Cut a 2 ¾” x 3 ½” access hole, positioned so that final
piping connections can be made by reaching through the
access hole. A generic cover plate can be used to cover
the hole after installation (sold separately).
Attach low voltage wires to ORIGINAL VACPAN
terminal connections marked “low voltage only”.
Slide ORIGINAL VACPAN into mounting slot and secure
to wall using two no. 6 screws provided.
Reach through access hole and make final fitting
connections.
22
FIGURE 47
ORIGINAL
VACPAN™
IN WALL INSTALLATIONS
COVER PLATE
SV382S
UNIVERSAL
SHORT 90° ELBOW
AH0002A
Page view 21