Page 1
MODELS QTXEN080FLT • QTXEN110FLT • QTXEN150FLT
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
8. This unit must be grounded.
CAUTION
!
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a
12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specification label on product for further informa-
tion and requirements.
QTXEN SERIES
FAN / LIGHT / NIGHT LIGHTS
READ AND SAVE THESE INSTRUCTIONS
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appear-
ance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the blower assembly (includes motor and impeller).
OPERATION
The fan, light, and night light can be operated separately. Use a
3-function wall control. Do not use a dimmer switch to operate
the light. See “Connect Wiring” for details. Use of speed controls
other than the NuTone Models 78V and 78W may cause a motor
humming noise.
WARRANTY
Installer: Leave this manual with
the homeowner.
BROAN-NUTONE THREE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products
that such products will be free from defects in materials or workmanship
for a period of three years from the date of original purchase. THERE ARE
NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
During this three-year period, Broan-NuTone will, at its option, repair or
replace, without charge, any product or part which is found to be defective
under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP
STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES,
FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSO-
RIES FOR DUCTING. This warranty does not cover (a) normal maintenance
and service or (b) any products or parts which have been subject to mis-
use, negligence, accident, improper maintenance or repair (other than by
Broan-NuTone), faulty installation or installation contrary to recommended
installation instructions.
The duration of an implied warranty is limited to the three-year period as
specified for the express warranty. Some states do not allow limitation on how
long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO
REP
AIR OR REPLACE, AT BROAN-
NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EX-
CLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL
NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL
DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT
USE OR PERFORMANCE. Some states do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitation
may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary from state to state. This warranty supersedes all prior
warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the
address or telephone number stated below, (b) give the model number and
part identification and (c) describe the nature of any defect in the product or
part. At the time of requesting warranty service, you must present evidence
of the original purchase date.
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027
www.nutone.com 888-336-3948
Register your product online at: www.nutone.com/register
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - FAN / LIGHT / NIGHT LIGHTS

Page 1MODELS QTXEN080FLT • QTXEN110FLT • QTXEN150FLT WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-JURY TO PERSONS, OBSERVE THE FOL

Page 2 - INSTALL HOUSING & DUCT

Page 2MODELS QTXEN080FLT • QTXEN110FLT • QTXEN150FLT TYPICAL INSTALLATIONSHousing mounted to I-joists.Housing mounted anywhere be-tween trusses usi

Page 3 - CONNECT WIRING

Page 3MODELS QTXEN080FLT • QTXEN110FLT • QTXEN150FLT 4. Connect electrical wiring. Run 120 VAC house wiring to installation location. Use proper

Page 4 - INSTALL GRILLE

Page 4MODELS QTXEN080FLT • QTXEN110FLT • QTXEN150FLT SERVICE PARTS99044460AKey No. Part No. Description 1 97016466 Housing 2 97016450 Duct

Page 5 - VENTILADOR/LÁMPARA/LÁMPARAS

Página 5MODELOS QTXEN080FLT • QTXEN110FLT • QTXEN150FLT ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS ELÉCTRICAS O LESIONES

Page 6 - VIGUETA “I”

Página 6MODELOS QTXEN080FLT • QTXEN110FLT • QTXEN150FLT INSTALACIONES TÍPICASPLANIFICACIÓN DE LA INSTALACIÓNMontaje de la cubierta en viguetas “I”.M

Page 7 - CONEXIÓN ELÉCTRICA

Página 7MODELOS QTXEN080FLT • QTXEN110FLT • QTXEN150FLT 4. Conecte los cables eléctricos. Extienda el cableado de la casa de 120 V CA al lugar de

Page 8 - INSTALE LA REJILLA

Página 8MODELOS QTXEN080FLT • QTXEN110FLT • QTXEN150FLT 99044460APIEZAS DE REPUESTOClave n.o Pieza n.o Descripción 1 97016466 2 97016450 3