Nutone Nm100WH User Manual

Browse online or download User Manual for Video surveillance systems Nutone Nm100WH. NuTone Nm100WH User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
MODEL NM100WH
Page 1
CAUTION
WARNING
!
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Read all instructions carefully before installing or using the
NM100 System.
2. TheNM100mustbeinstalledbyaqualieddealerorinstaller,
and must conform to all local building and electrical codes.
3. For continued protection against risk of re replace the fuse
in the power switch module only with the same type 3Amp,
250 Volt fuse.
4. Adhere to all warnings on the NM100 and in these instructions.
Follow all operating and installation instructions.
NM100 SERIES
SYSTEM INSTALLATION
READ AND SAVE THESE INSTRUCTIONS
THESE INSTALLATION INSTRUCTIONS ARE FOR USE BY
QUALIFIED PERSONNEL ONLY. TO REDUCE THE RISK OF
ELECTRIC SHOCK, DO NOT PERFORM ANY SERVICING
OTHER THAN THAT CONTAINED IN THE OPERATING
INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO.
Do not attempt to service the NM100 yourself as opening or
removing covers may expose you to dangerous voltage or other
hazards.Referallservicingtoqualiedservicepersonnel.
Thelightningashwitharrowheadsymbolwithinanequilateral
triangle is intended to alert the user to the presence of uninsulated
“dangerous voltage” within the product’s enclosure that may be
ofsufcientmagnitudetoconstituteariskofshocktopersons.
The exclamation point within an equilateral triangle is intended
to alert the user to the presence of important operating
and maintenance (servicing) instructions in the literature
accompanying the product.
• Locatethesystemawayfromheatsourcessuchasradiators,
heatregisters,stoves,orotherheatproducingproducts.
Do not locate the NM100 master or remote stations in an
outside wall.
• DonotexposetheNM100tomoisture.Doingsocancreatere
or shock hazards and void the warranty.
Do not place the NM100 master or remote stations in any wall
cavity with any other electrical wiring in the cavity.
Install the NM100 system after application of the wall
covering material.
• Donotexposetheoutdoorremotestationspeakerstosignicant
water contact. The outdoor remote speakers are weatherproof
but not waterproof. Continuous direct water exposure will cause
system problems.
Do not connect a remote or door station wire if you are unsure
of its terminating point. Connecting a door station to a remote
station may result in system damage.
Do ensure that all rough-in instructions have been followed
before power is applied to the NM100 system.
Do not splice cables. Splices are unreliable and defeat the signal
isolation properties of the cable.
Do not attach devices unauthorized for use with this system.
Authorized devices include:
Audio components connected via a line level input
NC300 6-disc player
• Ifextracableshavebeenrunforfuturespeakeradditions,care
must be taken to ensure these cables are not connected to the
NM100 master unit. Un-terminated cables (no station) connected
to the NM100 master may cause electrical feedback that will
damage the master station.
Do not over-tighten the screws for the remote stations or master
as the plastic face panels may crack or strip out.
• Use only NuTone certied replacement parts and have
them installed by a NuTone dealer or installer. Unauthorized
substitutionscanresultinre,electricshock,orotherhazards.
• Upon completion of any service or product repair, have the
dealer or installer conduct a safety check to ensure the system
is in proper operating condition.
Use only a damp cloth to clean the NM100 master and remote
stations. Do not use liquid cleaners or aerosol cleaners.
CAUTION: WIRING
• Aqualiedelectricianmustruna120VAClinetotheNM100
retrottransformers.
Individual wire runs should not exceed more than 350 FEET
of wire from any single remote station to the NM100 master or
1000 total feet for the entire system.
Label all wiring runs. ConnectingthewirestotheNM100master,
remote station or door stations incorrectly may result in system
damage.
Run a single cable from the master unit location to each remote
station and door station in a “home run” fashion. Do not loop
cable from one remote station to another.
Do not staple cables. Staples cause shorts.
Do not splice cables. Splices are unreliable and defeat the signal
isolation properties of the cables.
Do not run electrical wires through the rough-ins. If you encounter
120VACwiresrunningthrougharough-induringaretrotyou
musthaveaqualiedelectricianrerunthosewiresaroundthe
rough-in.
Page view 0
1 2 3 4 5 6 ... 31 32

Summary of Contents

Page 1 - SYSTEM INSTALLATION

MODEL NM100WHPage 1CAUTION WARNING ! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:1. Read all instructio

Page 2

MODEL NM100WHPage 10

Page 3

MODÈLE NM100WHPage 11ATTENTION AVERTISSEMENT ! AFIN DE DIMINUER LES RISQUES D’INCENDIE, D’ÉLECTROCUTION OU DE BLESSURES, SUIVEZ CES DIRECTIVES :1. Li

Page 4

MODÈLE NM100WHPage 12• Gardezlescâblesàaumoins46cm(18po)detouttubeuorescent,gradateurdelumièreetdesautrescâblages:câblageCA,

Page 5

MODÈLE NM100WHPage 13ENLÈVEMENT DE L’ANCIEN SYSTÈME D’INTERPHONEAvantd’enleverl’anciensystèmed’interphone,vériezquel’alimentationélectrique d

Page 6

MODÈLE NM100WHPage 14REMPLACEMENT DES STATIONS DES PIÈCESLes stations à distance et les stations de porte utilisent les mêmes câbles etboîtiersexist

Page 7

MODÈLE NM100WHPage 15INSTALLATION DU CHANGEUR DE CD NC300Branchez les câbles audio aux prises audio du lecteur NC300, telqu’illustré ci-de

Page 8 - APPENDIX A - NUTONE

MODÈLE NM100WHPage 16Placez les cavaliers que vous venez d’enlever dans la position à quatre lsillustréedanslaguresuivante.Suspendez la stati

Page 9 - APPENDIX B - M&S

MODÈLE NM100WHPage 173. Placezunlnudecavalier(dulàhaut-parleurdecalibre22convientaussi bien) entre les bornes S3 et S4.Suivez les é

Page 10 - MODEL NM100WH

MODÈLE NM100WHPage 18ANNEXE A – SYSTÈMES NUTONE*Reportez-vous aux cadres ci-dessous : • NF100MWH – Remplacement uniquement de la station principale

Page 11 - SÉRIE NM100

MODÈLE NM100WHPage 19ANNEXE B – SYSTÈMES M&S*Silesystèmeexistantestenboucleoupartiellementenboucle,ilnepeut être converti qu’en syst

Page 12 - INSTALLATION

MODEL NM100WHPage 2• Keepcablesat least 18 inches from uorescentlightxtures,dimmercontrols,andallotherwiring.ThisincludesACwirin

Page 13 - MODÈLE NM100WH

MODÈLE NM100WHPage 20

Page 14

MODELO NM100WHPágina 21PRECAUCIÓN ADVERTENCIA ! PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS ELÉCTRICAS O LESIONES PERSONALES, OBSERVE LA

Page 15

MODELO NM100WHPágina 22• No tienda cables eléctricos a través de los empalmes. Si encuentra cables de 120 VCA tendidos a través de un empalme durante

Page 16

MODELO NM100WHPágina 23CÓMO RETIRAR EL SISTEMA ANTIGUOAntes de quitar el sistema de interfono existente, asegúrese de quetoda la energía el

Page 17

MODELO NM100WHPágina 24REEMPLAZO DE LAS ESTACIONES DE HABITACIÓNLas estaciones de puerta y remotas utilizan el cable existente y los marcos

Page 18 - SYSTÈMES NUTONE

MODELO NM100WHPágina 25INSTALACIÓN DEL CAMBIADOR DE CD NC300Conecte los cables de audio a los conectores de audio del reproductor NC300,comoseindi

Page 19 - SYSTÈMES M&S

MODELO NM100WHPágina 26Coloque los puentes que acaba de desconectar en la posición de4cablesquesemuestraenlagurasiguiente.Cuelgue

Page 20

MODELO NM100WHPágina 273. Conecte un cable puente desnudo (un cable para altavoz calibre 22 funciona bien) entre las terminales S3 y S4.Siga

Page 21 - DE LA SERIE NM100

MODELO NM100WHPágina 28APÉNDICE A – SISTEMAS NUTONE *Consultelosmarcosqueseindicanacontinuación:• NF100MWH – Para reemplazar un sistema único

Page 22 - INSTALACIÓN

MODELO NM100WHPágina 29APÉNDICE B – SISTEMAS M&S*Si el sistema existente está en bucle, o parcialmente cableadoen bucle, sólo se pue

Page 23 - Página 23

MODEL NM100WHPage 3REMOVING THE OLD SYSTEMPrior to removing the existing intercom system make sure all power is turned off at the intercom locat

Page 24 - Página 24

MODELO NM100WHPágina 30

Page 25 - Página 25

MODEL NM100WHPage 31NOTES

Page 26 - Página 26

99044396ATwo Year Limited WarrantyWARRANTY OWNER: Broan-NuTone warrants to the original consumer purchaser of its products that such products will be

Page 27 - Página 27

MODEL NM100WHPage 4REPLACING THE ROOM STATIONSThe remote and door stations use the existing wire and station rough-in mounting frames or

Page 28 - SISTEMAS NUTONE

MODEL NM100WHPage 5INSTALLING THE NC300 CD CHANGERConnect the audio cables to the audio jacks of the NC300 player as showninthegurebelow.Afterc

Page 29 - SISTEMAS M&S

MODEL NM100WHPage 6Place the jumpers you just disconnected in the 4-wire position showninthenextgure.Suspend the master unit from the ro

Page 30 - Página 30

MODEL NM100WHPage 73. Connect a bare jumper wire (a 22 gauge speaker wire works well) between the S3 and S4 terminals.Follow the steps below to attac

Page 31

MODEL NM100WHPage 8APPENDIX A - NUTONE SYSTEMS*Refer to frames below: • NF100MWH – Replacing a master only system with an NM100 master • NF100CWH –

Page 32

MODEL NM100WHPage 9APPENDIX B - M&S SYSTEMS*If existing system is loop or partially loop wired, it can only beconverted to the IM5000

Comments to this Manuals

No comments