CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
4. For best capture of cooking impurities, your range hood should be
mounted so that the top of the hood is 24-30” above the cooking surface.
5. Please read specification label on product for further information and
requirements.
TABLE OF CONTENTS
This manual is divided into sections as follows:
“PREPARE HOOD LOCATION”
Run ductwork from roof or wall cap, and electrical wiring from service
panel - to installation location
“PREPARE THE HOOD”
Get your hood ready for installation
“CONNECT WIRING”
Make electrical wiring connections to hood
“INSTALL HOOD”
Secure hood to cabinet and ductwork - install bulbs and filters
“OPERATION”
How to use the hood controls
“CLEANING”
Keep your hood in top working condition
“SERVICE PARTS”
Part numbers and exploded view of hood components
“WARRANTY”
One-year limited warranty and how to contact us
NOTE If hood is to be installed Non-Ducted:
Purchase a set of (2) non-ducted filters from your
local distributor or retailer and attach them to the
aluminum mesh filters.
Patent No.:
US D450, 829 S
!
FOR DOMESTIC COOKING ONLY
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have
questions, contact the manufacturer at the address or telephone number
listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and
lock the service disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting means cannot
be locked, securely fasten a prominent warning device, such as a tag, to
the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards, includ-
ing fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent backdraft-
ing. Follow the heating equipment manufacturer’s guideline and safety
standards such as those published by the National Fire Protection As-
sociation (NFPA), and the American Society of Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
6. To reduce the risk of fire or electric shock, do not use this range hood
with an additional speed control device.
7. Ducted fans must always be vented to the outdoors.
8. To reduce the risk of fire, use only metal ductwork.
9. Use with approved cord-connection kit only.
10.This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers cause
smoking and greasy spillovers that may ignite. Heat oils slowly on low
or medium settings.
2. Always turn hood ON when cooking at high heat or when cooking flaming
foods.
3. Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the size of
the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A
RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray,
then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the
flames do not go out immediately, EVACUATE AND CALL THE FIRE
DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent steam
explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already know
how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
Register your product online at: www.nutone.com/register
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - RANGE HOOD

Page 1ALLURE® WS2 SERIESRANGE HOOD !ALLURE®WS2 SERIESRANGE HOODREAD AND SAVE THESE INSTRUCTIONSInstaller: Leave this manual with the homeowner.Home

Page 2 - PREPARE THE HOOD

Page 10ALLURE® WS2 SERIESRANGE HOOD CAMPANA EXTRACTORASERIE WS2 ALLURE®35,4 cm (campana de 76,2 cm)43,0 cm (campana de 91,4 cm)50,6 cm (campana de

Page 3

Page 11ALLURE® WS2 SERIESRANGE HOOD Página 11CAMPANA EXTRACTORASERIE WS2 ALLURE®PREPARACIÓN DE LA CAMPANA PREPARACIÓN DE LA CAMPANA4 Quite el cone

Page 4

Page 12ALLURE® WS2 SERIESRANGE HOOD Página 12CAMPANA EXTRACTORASERIE WS2 ALLURE® 12 Sólo para descarga horizontal: Quite la placa que se encuent

Page 5 - INSTALL HOOD

Page 13ALLURE® WS2 SERIESRANGE HOOD Página 13CAMPANA EXTRACTORASERIE WS2 ALLURE® CONEXIÓN ELÉCTRICA1 Haga la conexión eléctrica del suministro d

Page 6 - NON-DUCTED FILTERS

Page 14ALLURE® WS2 SERIESRANGE HOOD Página 14CAMPANA EXTRACTORASERIE WS2 ALLURE® OPERACIÓNVentilador y luces: 3 conmutadores de pulsadores para c

Page 7 - SERVICE PARTS

Page 15ALLURE® WS2 SERIESRANGE HOOD CAMPANA EXTRACTORASERIE WS2 ALLURE® PIEZAS DE SERVICIO CLAVE N.º PIEZA N.º DESCRIPCIÓN 1 R680508 Placa d

Page 8 - WARRANTY

Page 16ALLURE® WS2 SERIESRANGE HOOD 626980GGARANTIAGARANTIA NUTONE LIMITADA POR UN AÑONuTone garantiza al consumidor comprador original de sus prod

Page 9 - SERIE WS2 ALLURE

Page 2ALLURE® WS2 SERIESRANGE HOOD CABINETBOTTOMCABINET FRONTHORIZONTAL DUCTACCESS HOLE5¼"5¼"7½"1/8"¾"1315/16" (30&qu

Page 10 - PREPARACIÓN DE LA CAMPANA

Page 3ALLURE® WS2 SERIESRANGE HOOD PREPARE THE HOOD PREPARE THE HOOD4 Remove Damper/Duct Connector from inside the hood. Set connector aside - wit

Page 11 - DEFLECTOR

Page 4ALLURE® WS2 SERIESRANGE HOOD PREPARE THE HOOD11 Remove appropriate Duct Knockout(s) from top or back of hood.REARRECTANGULARDUCT KNOCKOUT(R

Page 12

Page 5ALLURE® WS2 SERIESRANGE HOOD CONNECT WIRINGWARNING: To reduce the risk of electric shock, make sure power is switched off at the service pane

Page 13 - INSTALACIÓN DE LA CAMPANA

Page 6ALLURE® WS2 SERIESRANGE HOOD OPERATIONWARNING: To reduce the risk of electric shock, discon-nect from power supply before cleaning.Aluminum m

Page 14 - OPERACIÓN

Page 7ALLURE® WS2 SERIESRANGE HOOD SERVICE PARTSKEY NO. PART NO. DESCRIPTION1 R680508 7” Round Duct Plate (includes hardware)2 R740013 Damper

Page 15 - PIEZAS DE SERVICIO

Page 8ALLURE® WS2 SERIESRANGE HOOD 626980GWARRANTYNUTONE ONE YEAR LIMITED WARRANTYNuTone warrants to the original consumer purchaser of its product

Page 16 - GARANTIA

Page 9ALLURE® WS2 SERIESRANGE HOOD CAMPANA EXTRACTORASERIE WS2 ALLURE®!ADVERTENCIAPARA REDUCIR EL RIESGO DE INCENDIO, CHOQUE ELECTRICO, O LESION A

Comments to this Manuals

No comments